Testec
Filter
- SKU:
- TT-CC 220
- Connection to oscilloscope or multimeter
- Measuring ranges: 10Apeak and 100Apeak AC/DC
- Output signal: 100mV/A and 10mV/A
- Bandwidth: DC to 300kHz
- Clamp opening: 11mm
- SKU:
- TT-CC 550
- Connection to oscilloscope or multimeter
- Measuring ranges: 5Apeak and 50Apeak AC/DC
- Output signal: 200mV/A and 20mV/A
- Bandwidth: DC to 500kHz
- Clamp opening: 11mm
- SKU:
- TT-CC 770
- Connection to oscilloscope or multimeter
- Measuring ranges: 7Apeak and 70Apeak AC/DC
- Output signal: 500mV/A and 50mV/A
- Bandwidth: DC to 1MHz
- Clamp opening: 10.3mm
- SKU:
- TT-CC 990
- Connection to oscilloscope or multimeter
- Measuring ranges: 4Apeak and 40Apeak AC/DC
- Output signal: 1000mV/A and 100mV/A
- Bandwidth: DC to 1.5MHz
- Clamp opening: 10.3mm
- SKU:
- TT-HV 200
- Passive high voltage oscilloscope probe
- 300MHz bandwidth
- Attenuation factor: x100
- Max. input voltage: 2kV (DC + peak AC)
- SKU:
- TT-HV 400
- Passive high voltage oscilloscope probe
- 300MHz bandwidth
- Attenuation factor: x100
- Max. input voltage: 4kV (DC + peak AC)
- SKU:
- TT-HVP08
- Passive high voltage oscilloscope probe
- 40MHz bandwidth
- Attenuation factor: x1000
- Max. input voltage: 8kV
- SKU:
- TT-HVP15 B
- Passive high voltage oscilloscope probe
- 40MHz bandwidth
- Attenuation factor: x1000
- Max. input voltage: 10kV
- SKU:
- TT-HVP2739
- Passive high voltage oscilloscope probe
- 50MHz bandwidth
- Attenuation factor: x1000
- Max. input voltage: 39kV
- SKU:
- TT-SI 7002
- Meets IEC/EN 61010-031:2015 safety standard
- Selectable attenuation settings of x20, x50 and x200
- 25MHz bandwidth @ x50 and x200 attenuation settings
- 15MHz @ x20 attenuation setting
- Up to ±700V (DC + AC peak) differential mode
- High accuracy (±2%)
- Power indicator LED
- Over range indicator LED
- SKU:
- TT-SI 7005
- Meets IEC/EN 61010-031:2015 safety standard
- Selectable attenuation settings of x1, x5 and x10
- 60MHz bandwidth @ x10 attenuation setting
- 50MHz bandwidth @ x5 attenuation setting
- 15MHz bandwidth @ x1 attenuation setting
- Up to ±35V (DC + AC peak) differential mode
- High accuracy (±2%)
- Power indicator LED
- Over range indicator LED
- SKU:
- TT-SI8010A
- Attenuation ratio: 1:100 and 1:1000
- Max. input voltage: 7000V
- 70MHz bandwidth
- Meets IEC 61010-1:2015 safety standard
- Selectable attenuation settings
- Offset setting function
- 5 MHz bandwidth limit function to remove noise and interferences.
- Overrange sound & light alarm
- High accuracy (±2%)
- Powered through USB or USB to mains adapter
- Over range indicator LED
- SKU:
- TT-SI 8010B
- Attenuation ratio: 1:100 and 1:1000
- Max. input voltage: 7000V
- 100MHz bandwidth
- Meets IEC 61010-1:2015 safety standard
- Selectable attenuation settings
- Offset setting function
- 5 MHz bandwidth limit function to remove noise and interferences.
- Overrange sound & light alarm
- High accuracy (±2%)
- Powered through USB or USB to mains adapter
- Over range indicator LED
- SKU:
- TT-SI 8050
- Attenuation ratio: 1:50 and 1:500
- Max. 1500V input voltage
- 70MHz bandwidth
- Meets IEC 61010-1:2015 safety standard
- Selectable attenuation settings
- Offset setting function
- 5 MHz bandwidth limit function to remove noise and interferences.
- Overrange sound & light alarm
- High accuracy (±2%)
- Powered through USB or USB to mains adapter
- Over range indicator LED
- SKU:
- TT-SI 8051
- Attenuation ratio: 1:50 and 1:500
- Max. 1500V input voltage
- 100MHz bandwidth
- Meets IEC 61010-1:2015 safety standard
- Selectable attenuation settings
- Offset setting function
- 5 MHz bandwidth limit function to remove noise and interferences.
- Overrange sound & light alarm
- High accuracy (±2%)
- Powered through USB or USB to mains adapter
- Over range indicator LED
- SKU:
- TT-SI 8052
- Attenuation ratio: 1:50 and 1:500
- Max. 1500V input voltage
- 200MHz bandwidth
- Meets IEC 61010-1:2015 safety standard
- Selectable attenuation settings
- Offset setting function
- 5 MHz bandwidth limit function to remove noise and interferences.
- Overrange sound & light alarm
- High accuracy (±2%)
- Powered through USB or USB to mains adapter
- Over range indicator LED
- SKU:
- TT-SI 8071
- Attenuation ratio: 1:10 and 1:100
- Max. input voltage: 700V
- 100MHz bandwidth
- Meets IEC 61010-1:2015 safety standard
- Selectable attenuation settings
- Offset setting function
- 5 MHz bandwidth limit function to remove noise and interferences.
- Overrange sound & light alarm
- High accuracy (±2%)
- Powered through USB or USB to mains adapter
- Over range indicator LED
- SKU:
- TT-SI 8110
- Attenuation ratio: 1:100 and 1:1000
- Max. input voltage: 2800V
- 100MHz bandwidth
- Meets IEC 61010-1:2015 safety standard
- Selectable attenuation settings
- Offset setting function
- 5 MHz bandwidth limit function to remove noise and interferences.
- Overrange sound & light alarm
- High accuracy (±2%)
- Powered through USB or USB to mains adapter
- Over range indicator LED
- SKU:
- TT-SX 200
- Attenuation ratio: 1:10
- Max. 60V input voltage
- 200MHz bandwidth
- Offset setting function
- Overrange alarm
- High accuracy (±2 %)
- Power supply via USB or USB mains adaptor
- SKU:
- TT-SX 9001
- Shipping weight:
- 0,64 kg
- Item weight:
- 0,64 kg
- Differential oscilloscope probe
- Bandwidth: 30MHz
- Attenuation ratio: x10, x100
- Risetime: 14 ns
- SKU:
- TT-SX 9002
- Shipping weight:
- 0,64 kg
- Item weight:
- 0,64 kg
Differential oscilloscope probe
Bandwidth: 30MHz
Attenuation ratio: 1:20 / 1:200